Driver Hänel Rotomat

Module Hänel Rotomat

This module supports Hänel Rotomat lifts, equipped with the MP0A controller and a serial connection. The PC with Shark Control can be connected either directly or using a Moxa Box for Ethernet support.

There can be some issues, regarding security. Depending on the configuration, it can be necessary to confirm on the Hänel keyboard. The procedure to pick is:

  1. Shark get the tray.
  2. The operator picks the articles and breaks the light curtain.
  3. The operator must press “confirm” on the Rotomat, it can not be done in the opposite direction (confirm before breaking the light).


The display when confirmation on the Rotomat is required.


Shark used to control a Hänel Rotomat.

Configuration of Shark

The lift must be defined in the Shark Registry under devices.verticallifts.<modulename>

Registry Parameter Values Description    
         
Type RotomatMP0A      
Connection COM1* *COM2.. MOXAGATEWAY:<ip>:<port> Connection port to the machine.
Unit 1..99 Lift number, default is 1.    
  1.. Default is 0. The max tray number in the automat. If 0 it will be auto configured from what is read from the Rotomat.    
MaxTrayNumber        

Configuration of the Hänel Rotomat

Before installation, check that the serial cable from the X10 connector is available. This cable is required to connect the lift to a serial connector.

To enter setup mode for Rotomat, press: CE CE RETURN CE CE RETURN

Set the parameters:

Parameter Value Note
GERÂTENUMMER (Lift Number) 1 First machine, where the PC is connected must be 1. This is in Shark, the Unit Number.
PROGRAMVERSION AUTOSTART BURO Allow the Shark to control the Rotomat.
DATENRUCKMELDUNG JA  

The BCD switch on the network card (where the X10 connector is) must be set to “0”.

The Serial Cable

The cable is connected to the connected X10 and is supplied by Hänen (it looks like a standard 26 wire ribbon cable with a 25 pins female D-SUB connector).

 
The network interface in the Rotomat.

The connections to the 25 pins D-SUB female connector:

D-SUB 25 pins Female Connector
Cable from Hänel

Connection to D-SUB 9 Male connector.
 

2

2 Rx

3

3 Tx

7

5 (GND)

Please note, this is not a normal “Serial Female DB25/Male DB9 Adapter”, pin 2 and 3 is “swapped”.

The communication is RS232, and must be set to 9600 baud, 8 data bit, 1 stop bit, no parity.

An alternative solution to use the cable described above, could be to connect via a 26 wire ribbon-cable directly to a Moxa Box.

Commands

Commands supported by this module. Two special commands can be helpfuld to debug problems:

MSTATUS?   
Will send a status request to the Automat and return the response.

CMD <cmd>
Will append a <cr><lf> to the <cmd> and write it directly to the module. Can be used for low level testing.

ARRIVALTIME?

Returns the absolute time in ms when the tray is expected in the gate

AUTOCONFIG

BUSY?

CMD

Send a raw command to the automat

       
Parameter Type Default Description
Command STR   Instrument command to send

DEBUG

Enable/disable debug printouts

                   
Parameter Type Default Description            
Function STR ALL ALL LOWLEVEL EVENTS BOXTRACE TELEGRAMS STATUSLOOP REGISTERACCESS</span>
Mode BOOLEAN yes If true debug messages will be printed to standard output            

DEBUG?

GETTRAY

Get a tray to the gate

       
Parameter Type Default Description
TrayNumber INTEGER   Tray number
ID STR   User supplied ID
Tilt BOOLEAN off Enable/disable tilt of tray
TrayHeight FLOAT 0.0 Height of tray
LightXPos FLOAT 0 X Location 0 -1
LightYPos FLOAT 0 Y Location 0 -1
LightXWidth FLOAT 0 X Width Location 0 -1
LightYDepth FLOAT 0 Y Width Location 0 -1
NextTray INTEGER 0 Next tray expected to following current tray

GETTRAY?

Request the specified tray and returns the time when the tray is expected in the gate

       
Parameter Type Default Description
TrayNumber INTEGER   Tray number
ID STR   User supplied ID
Location STR   Shark location address

GT

Simple get for turbo trays

       
Parameter Type Default Description
Tray INTEGER 0  
TurboTray INTEGER 0  

HELP?

       
Parameter Type Default Description
Command STR   Command name

HELPHTML?

       
Parameter Type Default Description
Filename STR /users/sos/tmp/helphtml.htm help.html

INIT

Initilize the automat connection

       
Parameter Type Default Description
Port STR   The port used to connect to the Automat
Address STR   Automat address on the PLC network

LIFT

Set the lift

       
Parameter Type Default Description
Height FLOAT 1.0 Lift height in meter

LIFT?

Set the lift

LOADREG

Load setup from the Shark Registry

MSTATUS?

Read the automat status, blocking!

REGISTEREVENTHANDLER

REGMONITOR

Setup up a monitor that will read PLC registers continously and send the result as an event when data is changed

       
Parameter Type Default Description
Register STR   Start register to monitor
Length INTEGER 1 Lenght of number block
Interval INTEGER 1000 Interval in ms to monitor
RepeatCount INTEGER 1 Number of times to repeat

REPORT?

Returns a module specific status report

RESETERROR

RESTART

Reset the module to the original state

RETURNTRAY

SAVEREG

Save current setup to the Shark Registry

SERIAL:CLEAR

SERIAL:CLOSE

SERIAL:DEBUG

Enable/disable debug printouts

                   
Parameter Type Default Description            
Function STR ALL ALL LOWLEVEL EVENTS BOXTRACE TELEGRAMS STATUSLOOP REGISTERACCESS</span>
Mode BOOLEAN yes If true debug messages will be printed to standard output            

SERIAL:DEBUG?

SERIAL:DEBUGLEVEL

       
Parameter Type Default Description
Level INTEGER 0 0: None, 1: Normal log, 2: Detailed

SERIAL:HELP?

       
Parameter Type Default Description
Command STR   Command name

SERIAL:HELPHTML?

       
Parameter Type Default Description
Filename STR /users/sos/tmp/helphtml.htm help.html

SERIAL:LIST?

SERIAL:LOADREG

Load setup from the Shark Registry

SERIAL:OPEN

           
Parameter Type Default Description    
Port STR COM1 COM port number to use for the connection    
Baudrate INTEGER 9600 Baudrate    
Databits INTEGER 8 Databits    
Stopbits INTEGER 1 Stopbits    
Parity STR none none even odd</span>

SERIAL:PING?

SERIAL:READ?

SERIAL:READFIXED?

       
Parameter Type Default Description
Count INTEGER 1 Number of bytes to read

SERIAL:REGISTEREVENTHANDLER

SERIAL:REPORT?

Returns a module specific status report

SERIAL:RESET

SERIAL:RESTART

Reset the module to the original state

SERIAL:SAVEREG

Save current setup to the Shark Registry

SERIAL:STATUS?

Returns the current status for the module

SERIAL:TERMINATOR

       
Parameter Type Default Description
Terminator INTEGER 10 Decimal value of terminator character

SERIAL:TERMINATOR?

SERIAL:TERMINATORCHARACTER

       
Parameter Type Default Description
Terminator STR ! Character used for read termination

SERIAL:WRITE

       
Parameter Type Default Description
Command STR   Text string that will be written to the serial port

SERIAL:WRITEBYTES

       
Parameter Type Default Description
IntegerList INTEGER_ARRAY   List of ASCII values as integer representation

SERIAL:WRITELINE

       
Parameter Type Default Description
Command STR   Text string that will be written to the serial port

STATE?

STATUS:COUNT?

STATUS:DEBUG

Enable/disable debug printouts

                   
Parameter Type Default Description            
Function STR ALL ALL LOWLEVEL EVENTS BOXTRACE TELEGRAMS STATUSLOOP REGISTERACCESS</span>
Mode BOOLEAN yes If true debug messages will be printed to standard output            

STATUS:DEBUG?

STATUS:ERROR?

STATUS:HELP?

       
Parameter Type Default Description
Command STR   Command name

STATUS:HELPHTML?

       
Parameter Type Default Description
Filename STR /users/sos/tmp/helphtml.htm help.html

STATUS:LOADREG

Load setup from the Shark Registry

STATUS:REGISTEREVENTHANDLER

STATUS:REPORT?

Returns a module specific status report

STATUS:RESET

STATUS:RESTART

Reset the module to the original state

STATUS:SAVEREG

Save current setup to the Shark Registry

STATUS:STATUS?

Returns the current status for the module

STATUS?

Returns the current status for the module

TILTSUPPORTED

Define if the automat supports tray tilt

       
Parameter Type Default Description
Supported BOOLEAN false If true tray tilt is supported

TILTSUPPORTED?

Returns if the automat supports tray tilt

TRAY:ADD

Add a tray to the Shark configuration (does not make any changes in the lift)

       
Parameter Type Default Description
TrayNumber INTEGER   Tray number to add
Position INTEGER   Position of the tray
Height INTEGER   Height of the tray in mm

TRAY:ADDGROUP

Adds a serie of trays, mainly for debugging

       
Parameter Type Default Description
FromTrayNumber INTEGER   First tray to add
ToTrayNumber INTEGER   Last tray to add

TRAY:DEBUG

Enable/disable debug printouts

                   
Parameter Type Default Description            
Function STR ALL ALL LOWLEVEL EVENTS BOXTRACE TELEGRAMS STATUSLOOP REGISTERACCESS</span>
Mode BOOLEAN yes If true debug messages will be printed to standard output            

TRAY:DEBUG?

TRAY:EMPTYPOS?

Returna an empty position with the requested height. Will not allocate anything.

       
Parameter Type Default Description
Height INTEGER 0 Height in mm of requested position

TRAY:FREELIST?

Returns a list of free positions with total free height

TRAY:HELP?

       
Parameter Type Default Description
Command STR   Command name

TRAY:HELPHTML?

       
Parameter Type Default Description
Filename STR /users/sos/tmp/helphtml.htm help.html

TRAY:INFO?

Returns info about the selected logical tray: position, tray, tray_heigh, back, distance, pos_height

       
Parameter Type Default Description
tray INTEGER 0 Logical Tray Number (empty shows all)

TRAY:LIST?

Return a list of all trays for the lift

TRAY:LOADREG

Load setup from the Shark Registry

TRAY:POSITION

Set info for the specified position

       
Parameter Type Default Description
position INTEGER 0 Position
tray INTEGER 0 Tray Number
height INTEGER -1 Height in mm of the position
back INTEGER -1 0=Front, 1=Back
type INTEGER -1 1=Tray
distance INTEGER -1 Encoder value
tray_height INTEGER -1 Height in mm of the tray if present

TRAY:POSITION?

Returns info about the selected position: tray, heigh, back, distance, type

       
Parameter Type Default Description
position INTEGER   Position Number

TRAY:REGISTEREVENTHANDLER

TRAY:REMOVE

Remove a tray from Sharks configuration

       
Parameter Type Default Description
TrayNumber INTEGER   Tray number to add

TRAY:REMOVEALL

Remove all trays from Sharks configuration

TRAY:REPORT?

Returns a module specific status report

TRAY:RESTART

Reset the module to the original state

TRAY:SAVEREG

Save current setup to the Shark Registry

TRAY:STATUS?

Returns the current status for the module

TRAY?

TRAYACCEPT

Accept the current tray height

       
Parameter Type Default Description
accept BOOLEAN no If true accept the current tray height

TURBOSUPPORTED

Define if the automat supports turbo mode

       
Parameter Type Default Description
Supported BOOLEAN false If true turbo is supported

TURBOSUPPORTED?